Graco Husky Diaphragm pump
The products of this brand in the series, the HUSKY are provided to our customers in that market with the name of diaphragm pump Husky also be known. For more information you can go to catalog diaphragm pump گراکو direction or notice from the last price to the page list, price, diaphragm pump گراکو, please visit.
Introduction Graco Husky Diaphragm pump
Visits chemistry. for visit this page on the mobile, etc. please check the direction of the sighting full tables, when the tables are the image to the left or right (some tables because of the magnitude may be in your display for the perfect display. if can also make your phone horizontally to get the tables to see better.).
Technical specifications
A variety of Graco Husky Diaphragm pump
For more information, please click on the series about the terms in the table below.
Diaphragm pump گراکو Husky 205 | Graco Husky Diaphragm pump 307 |
Graco Husky Diaphragm pump 515 | Diaphragm pump گراکو Husky 716 |
Diaphragm pump گراکو Husky 1050 | Diaphragm pump گراکو Husky 1590 |
Diaphragm pump گراکو Husky 2150 | Diaphragm pump گراکو Husky 3300 |
How to choose the Graco Husky Diaphragm pump
Parts number on the ID tag in the central part of all pumps, diaphragm گراکو Husky (Graco Husky) is located.
D X X X X X
D: diaphragm pump
X: size Pump
X: body material
X: The Living Room,
X: ball
X: diaphragm
Aperture | Ball | Living room | Body material | The size of the pump (inch) |
1 = PTFE | 1 = PTFE | 2 = Acetal | 1 = (Acetal (npt | 1 = 1/4 PP |
5 = TPE | 2 = Acetal | 3 = Stainless Steel | 2 = (Poly (npt | 2 = 1/4 PP |
6 = Santoprene | 3 = Stainless Steel | 4 = Hardened SST | 3 = (Aluminium (npt | 3 = 3/8, AL |
7 = Buna N | 4 = Hardened SST | 5 = TPE | 4 = Stainless Steel (npt | 5 = 1/2 PP |
8 = Fluoroelastomer | 5 = TPE | 6 = Santoprene | 5 = (PVDF (npt | 4 = 1/2 PP |
Geolast = G | 6 = Santoprene | 7 = Buna N | 6 = (Ductile Iron (npt | 5 = 3/4, PP |
– | 7 = Buna N | 8 = Fluoroelastomer | Acetal A = | 4 = 3/4, PP |
– | 8 = Fluoroelastomer | 9 = Polypropylene | Poly = B | B = 1.1/2 AL |
– | 9 = Polypropylene | PVDF = A | Aluminum = C | C = 1.1/2 AL |
– | PVDf = A | SST with Viton Seal = B | Stainless Steel = D | T = 1.1/2 SS |
– | Geolast = G | Santoprene with Viton Seal = C | PVDF = E | U = 1.1/2 SS |
– | – | Geolast = G | Ductile Iron, F = | F = 2 AL |
– | – | – | G = 2 bsp Alum Extened | G = 2 AL |
– | – | – | H = 2 ” npt Alum Extened | V = 2 SS |
Determine the kit diaphragm pump
When choosing a kit, from the same code number for the pump about the size, living room, etc. a hub-and-diaphragm pump use.
D O X X X X
D : diaphragm pump
O : kit
X : size Pump
X : the living room,
X : Hub
X : diaphragm
Aperture | Hub | Living room | The size of the pump |
1 = Teflon (PTFE) | 1 = Teflon (PTFE) | 0 = No Ball | 1 = 6.35 mm (1/4 inch) |
5 = thermo plastic elastomer (TPE) | 2 = stall (Acetal) | 2 = stall (Acetal) | 3 = 9.52 mm (3/8 inch) |
6 = سنتوپرن | 3 = stainless steel | 3 = stainless steel | 5 = 12.7 mm (1/2 inch) and 19.05 mm (3/4 inch) |
7 = Buna N | 4 = Hardened SST | 4 = Hardened SST | 25.4 mm (1 inch) reference to the Husky 1050 |
8 = Fluoroelastomer | 5 = thermo plastic elastomer (TPE) | 5 = thermo plastic elastomer (TPE) | B = 38.1 mm (1.1/2 inch) pump metal |
Geolast = G | 6 = سنتوپرن | 6 = سنتوپرن | C = 38.1 mm (1.1/2 inch) pump plastic |
0 = No Ball | 7 = Buna N | 7 = Buna N | F = 50.8 mm (2 inch) pump metal |
– | 8 = Fluoroelastomer | 8 = Fluoroelastomer | G = 50.8 mm (2 inch) pump plastic |
– | 9 = polypropylene | 9 = polypropylene | K = 76.2 mm (3 inch) |
– | A = کاینار (PVDF) | A = کاینار (PVDF) | – |
– | Geolast = G | B = SST with Viton Seal | – |
– | 0 = No Ball | C = Santoprene with Viton Seal | – |
– | – | Geolast = G | – |
A variety of materials Graco Husky Diaphragm pump
Stall (material used in the body, Ball, and living room)
- Resistance against a wide range solvents
- Tolerance and resistance to high
- Abrasion resistance
- Applicable to flammable material
- Unsuitable for use with acids and bases
Aluminum (material used in the body and the air motor)
- Resistance to corrosion and abrasion, the average
- Unsuitable for use with hydrocarbons Graco Husky Diaphragm pump
Iron (material used in the body)
- High resistance against abrasion
HARDENED SST (material used in the living room and the ball)
- Chemical resistance temperature
- Wear-resistant
- Ball and living room, resistant to abrasion
PVDF (material used in the body, and living room)
- Chemical resistance strong against acids and bases
- Wear-resistant
- Resistance to high temperature
Polypropylene (material used in the air of the engine, body, etc., living room, and ball)
- Wide chemical compatibility
- Multi-purpose
- Replacement cheap price
Stainless steel (material used in the air of the engine, body, etc., living room, and ball)
- High resistance against corrosion and abrasion
BUNA-N (material used in the living room, ball, and diaphragm)
- Suitable for Fluid Base Oil
- Unsuitable for strong solvents and chemicals
- Is food
GEOLAST (material used in the living room, ball, and diaphragm)
- Wear-resistant
- Chemical compatibility similar with BUNA-N and TPE
TPE (material used in the living room, ball, and diaphragm)
- Wear-resistant
- The perfect alternative BUNA-N
(material used in the living room, ball, and diaphragm)
- Resistant to abrasion and chemicals
- Unsuitable for solvents or hydrocarbons
- Suitable alternative, EPDM or EPR
- Is food
Teflon PTFE (material used in the ball, and diaphragm)
- Great for solvents
- Abrasion resistance poor
- Wide chemical compatibility with fluids
- Is food
FLUOROELASTOMER (material used in the living room, ball, and diaphragm)
- Level high resistance against corrosion by acids
- Is food
HASTELLOY (material used in the body)
- Resistant to harmful chemicals and corrosive environments
- Compatible with liquids of high temperature
Characteristic | HUSKY 205 | HUSKY 307 | HUSKY 515 | HUSKY 716 |
Body material | ACETAL, PP, PVDF | ACETAL, PP | ACETAL, PP, PVDF | AISI316 and aluminum |
Size inlet/outlet (inch) | 1/4 | 3/8 | 1/2 | 3/4 |
The size of the fitting forecast (inch) | 1/4 | 1/4 | 1/4 | 1/4 |
Max flow rate (liters per minute) | 18.9 | 26.5 | 57 | 61 |
Maximum air pressure supply (Times) | 7 | 7 | 7 | 7 |
Max head (m) | 70 | 70 | 70 | 70 |
Maximum capacity خودمکشی (m dry) | 3 | 3.7 | 4.5 | 4.5 |
The maximum diameter of the particles, Ts (MM) | 1.5 | 1.5 | 2.5 | 2.5 |
Noise level (DB) | 70 | 75 | 74 | 74 |
Displacement per cycle (CC) | 45 | 76 | 150 | 150 |
Max viscosity (CP) | 500 | 1000 | 5000 | 7000 |
Catalogue | Catalogue of the pump Husky 205 | Catalogue of the pump Husky 307 | Catalogue of the pump Husky 515 | Catalogue of the pump Husky 716 |
Characteristic | HUSKY 1050 | HUSKY 1590 | HUSKY 2150 | HUSKY 3300 |
Body material | PP, PVDF, AISI316, HASTELLOY, aluminum, | PP, PVDF, AISI316, and aluminum | PP, PVDF, AISI316, DUCTIL IRON, and aluminum | PP, AISI316, and aluminum |
Size inlet/outlet (inch) | 1 | 1.1/2 | 2 | 2 |
The size of the fitting forecast (inch) | 1/2 | 1/2 | 1/2 | 3/4 |
Max flow rate (liters per minute) | 189 | 378.5 | 568 | 1059 |
Maximum air pressure supply (Times) | 8.6 | 8.4 | 8.4 | 7 |
Max head (m) | 86 | 84 | 84 | 70 |
Maximum capacity خودمکشی (km) | 4.9 (dry) 8.8 (wet) |
6.1 (dry) | 5.48 (dry and wet) | 2.4 (dried) 8.5 (wet) |
The maximum diameter of particles (mm) | 3.2 | 4.8 | 6.3 | 13 |
Noise level (DB) | 78 | 77 | 78 | 98 |
Displacement per cycle (L) | 640 CC | 1.96 | 3.9 | 6.9 |
Max viscosity (CP) | 10000 | 15000 | 20000 | 20000 |
Catalogue | Catalogue of the pump Husky 1050 | Catalogue of the pump Husky 1590 | Catalogue of the pump Husky 2150 | Catalogue of the pump Husky 3300 |
The advantages of diaphragm pump Husky
- The ability to control and adjust Dubai and pressure pumping with the change of air pressure consumption
- Ability to function dry
- Ability to install in the settings package
- Portable has been in place in different installation is.
- Leakage at least the best choice of the direction of the fluid, toxic, corrosive, and flammable and explosion
- Explosion-proof
- Remove the mechanical flood of the building, they
- Ability to immersion in fluid
- Easy operation
- Self-Prime and no need to bleed
- Ability to install in above the fluid level, etc. sublevels fluid and immersed within the fluid
- Repairs and maintenance easy